Acrulog IPX H2S Parts Per Million Monitor
Continuous, in-situ, H2S environmental gas monitoring with micro sampling technology (MST)
Acrulog IPX H2S Parts Per Million Monitor
The Acrulog™ IPX H2S Parts Per Million Monitor (PPM) is designed for indoor and outdoor continual use and will record levels (0-20PPM, 0-50PPM, 0-200PPM, or 0-1000PPM) of H2S with memory backup.
Standard model features built-in 4-20mA industrial output, internal batteries and is compatible with an external power input via the waterproof cable provided (5-24VDC). Optional outputs: RS485, 4G LTE-M or NB-IoT.
All logged data can then be easily logged and downloaded via Bluetooth® wireless technology and viewed in the custom graphing and data analysis Acrustat software.
Available to purchase or rent enquire
Download produce brochure here
FEATURES & BENEFITS
Wireless download of data via Bluetooth® technology
Battery backup with 2 x 1.5v D Alkaline batteries up to 21 days
Battery backup with 2 x 3.6v D Lithium batteries up to 60 days
4 - 20mA communication on standard model
Large, clear, informative alpha - numeric display
External filter for easy replacement
Easy to download data using custom Acrustat software
Customized case with easy access to change batteries (no tools required)
Optional Outputs:
- RS485
- 4G LTE-M or NB-IoT
Typical applications
Odour and corrosion control
Manhole and wet well monitoring
Asset management and research studies
Wastewater treatment plant monitoring
Ventilation pipes and rising mains
specifications
Feature | Specifications |
---|---|
Measurement Range |
|
Zero Drift | < +/- 1ppm at NTP (Normal temperature and pressure) |
Accuracy | < +/- 10% of reading over range at NTP Calibrated on 50ppm |
Instrument Temp Range | -10C to 50C (14F — 122F) |
Sensor Temp Range | -10C to 50C (14F — 122F) |
Relative Humidity Range | 0-100% non-condensing |
Ingress Protection | Housed in a modified IP67 case |
External Dimensions | 205mm x 97mm x 63mm 1 (8” x 3.8” x 2.5”) |
Instrument Weight | 3850 grams with Alkaline batteries fitted (30oz / 1.8 pounds) |
Logging Interval | 10 minutes to 18 hours |
4-20mA Output | Externally powered loop 12-24 volts DC (4 - 20mA output updated every second for connection to flash powered sampling loops) |
Power Supply External (with 4-20mA or RS485) | External 5-24 volt DC supply (Average 20mA with peak of 50mA) |
Internal Power Supply | 2 x 3.6v D size Lithium or 2 x 1.5v D size Alkaline batteries |
Humidity Accuracy | +/- 5% RH @ 55% RH |
Humidity Sensor Range | 0-100% |
Temperature Accuracy | +/- 0.3 @ 25C (77F) |
Optional Output Upgrades |
|
Warranty | 12 Months |