Acrulog IPX H2S Dilution Monitor
Continuous, high level PPM H2S gas monitoring with extended sample draw capability and
micro sampling technology (MST)
Acrulog IPX H2S Dilution Monitor
The Acrulog™ IPX H2S Dilution Monitor is designed for indoor and outdoor continual use and will record levels (0-20ppm, 0-50PPM, 0-200ppm, or 0-1000ppm) of H2S and features remote-draw sampling capability and memory backup.
The Acrulog™ IPX H2S Dilution Monitor is designed for long term continual use to record high PPM levels of H2S. The H2S monitor uses a built-in sample pump & dilution system designed for precision mixing of filtered air to reduce sensor exposure and moisture. The H2S monitor is capable of drawing a remote sample from up to 15 meters away with custom sample line & fittings.
Standard model features built-in 4-20mA industrial output, internal battery back-up and is compatible with an external power input via the waterproof cable provided (5-24VDC). Optional outputs: RS485, 4G LTE-M or NB-IoT
All logged data can then be easily logged and downloaded via Bluetooth® wireless technology and viewed in the custom graphing and data analysis Acrustat software.
Available to purchase or rent enquire
Download produce brochure here
FEATURES & BENEFITS
Designed for long term monitoring of high levels of PPM gas
Wireless download of data via Bluetooth® technology
Battery backup: 2 x 1.5v Alkaline or 3.6v Lithium D size batteries
Logging capacity of 3 million data points
Large, clear, informative alpha-numeric display
Easy to download data using custom Acrustat software
Modified IP67 case with easy access to change batteries (no tools required)
Touch switch to access main menu
Remote sampling up to 15 meters (50 feet)
Special PPB model for extended sampling
Optional Outputs:
- RS485
- 4G LTE-M or NB-IoT
Typical applications
Odour and corrosion control
Manhole and wet well monitoring
Asset management and research studies
Wastewater treatment plant monitoring
Ventilation pipes and rising mains
Optional Extras
specifications
Feature | Specifications |
---|---|
Measurement Range |
|
Zero Drift | < +/- 1ppm at NTP (Normal temperature and pressure) |
Accuracy | < +/- 10% of reading over range at NTP Calibrated on 50ppm |
Instrument Temp Range | -10C to 50C (14F — 122F) |
Sensor Temp Range | -10C to 50C (14F — 122F) |
Relative Humidity Range | 0-100% non-condensing |
Remote Sample Draw Range | Up to 15 meters (50 feet) with custom sample line to suit application | Ingress Protection | Housed in a modified IP67 case |
External Dimensions | 205mm x 97mm x 63mm (8" x 3.8" x 2.5") |
Instrument Weight | 850 grams with batteries fitted (30oz / 1.8 pounds) |
Logging Interval | 10 minutes to 18 hours |
4-20mA Output | Externally powered loop 12-24 volts DC (4-20mA output updated every second for connection to flash powered sampling loops) |
Power Supply External (with 4-20mA or RS485) | External 5 - 24 volt DC supply (Average 30mA with peak of 50mA) |
Internal Battery Backup | 2 x 3.6v D size Lithium batteries |
Humidity Accuracy | +/- 5% RH @ 55% RH |
Temperature Accuracy | +/- 0.3 @ 25C (77F) |
Output Options |
|